3D imaging with a single-sided sensor: an open tomograph

separator-line

An open tomograph to image volume regions near the surface of large objects is described. The central achievement in getting such a tomograph to work is the design of a fast two-dimensional pure phase encoding imaging method to produce a cross-sectional image in the presence of highly inhomogeneous fields. The method takes advantage of the multi-echo acquisition in a Carr-Purcell-Meiboom-Gill (CPMG)-like sequence to significantly reduce the experimental time to obtain a 2D image or to spatially resolve relaxation times across the sensitive volume in a single imaging experiment. Depending on T(2) the imaging time can be reduced by a factor of up to two orders of magnitude compared to the one needed by the single-echo imaging technique. The complete echo train decay has been also used to produce T(2) contrast in the images and to spatially resolve the T(2) distribution of an inhomogeneous object, showing that variations of structural properties like the cross-link density of rubber samples can be distinguished by this method. The sequence has been implemented on a single-sided sensor equipped with an optimized magnet geometry and a suitable gradient coil system that provides two perpendicular pulsed gradient fields. The static magnetic field defines flat planes of constant frequency parallel to the surface of the scanner that can be selected by retuning the probe frequency to achieve slice selection into the object. Combining the slice selection obtained under the presence of the static gradient of the open magnet with the two perpendicular pulsed gradient fields, 3D spatial resolution is obtained.

Author:

Perlo, J. and Casanova, F. and Blumich, B.

Year:

2004

Volume:

166

Pages:

228-35--

Keywords:

Equipment Design Image Enhancement/*instrumentation/methods *Imaging, Three-Dimensional Magnetic Resonance Spectroscopy/*instrumentation/*methods Magnetics/instrumentation Phantoms, Imaging Quality Control Reproducibility of Results Sensitivity and Specificity Tomography/*instrumentation/*methods Transducers

Comment:

Perlo, J Casanova, F Blumich, B Research Support, Non-U.S. Gov't United States Journal of magnetic resonance (San Diego, Calif. : 1997) J Magn Reson. 2004 Feb;166(2):228-35.

Address:

Institut fur Technische und Macromolekulare Chemie, RWTH Aachen D-52056, Germany.

Book title:

J Magn Reson

Copyright@ All right reserved by imrs2000.com 1998-2019.

Disclaimer: These statements have not been evaluated by the Food and Drug Administration. This product is not intended to diagnose, treat, cure or prevent any disease. If you are pregnant, nursing, taking medication, or have a medical condition, consult your physician before using this product. This information is not intended as medical advice and may not be used as medical advice. It should not be used to replace the advice of your own doctor.

facebook
youtube
instagram
imrs 2000 logo

Visit mobile website: m.imrs2000.com

Web Design & SEO by Kardash & Sons